PROJECTS
Hospitals
NO | PROJECT | CLIENT | SCOPE OF WORK | STATUS /COST |
1. |
KeningauHospital (240 beds), located in Sabah. |
York Sales & Services Sdn. Bhd. And Arab-Malaysian Blue Star Sdn. Bhd. For U.E. Concstructions. |
Mechanical HVAC on-site noise control analysis, and remedial work design for the HVAC systems i.e. FCU, AHU systems. Particular design attention was placed to achieve acceptable noise criteria within the occupied areas, based on the stringent site constraint. |
Completed Value: Undisclosed |
2. |
SungaiPetaniHospital, located in Kedah. |
M-KAP Engineering Sdn. Bhd. for KTA Tenaga. |
Mechanical Noise Control analysis, and design for the Chiller and Cooling Tower Block. Particular design attention was placed to achieve acceptable noise criteria within the limit as stipulated by JKR noise specifications. |
Completed Value: Undisclosed |
3. |
SerdangHospital, located in Putrajaya. |
Kruvent Industries (M) Sdn. Bhd. For Konsortium Ranhill Sdn. Bhd/KJ Engineering Sdn. Bhd. |
Mechanical noise control analysis, and design for the HVAC systems for the Isolation Ward and Isolation Rooms. Mechanical noise control for high static pressure and 100% fresh air system. |
Completed Value: Undisclosed |
4. |
PandanHospital, Operation Theatre 1, Kuala Lumpur. |
Nam Foong (M) Sdn. Bhd. For M-KAP Engineering Sdn. Bhd. |
Mechanical Noise Control analysis, and design for Supply Air Air-conditioning serving the Operation Theatre 1 to meet NC 25 noise criteria. Particular design attention was placed to achieve acceptable noise criteria within the limit as stipulated by JKR noise specifications. |
Completed Value: Undisclosed |
5. |
ASSUNTAHospital Extension Block, Petaling Jaya. |
Kejuruteraan Bintai Kindenko Sdn. Bhd. |
Mechanical HVAC Noise Control and Vibration Analysis with detailed review on the AHU, FCU outdoor chiller systems that have already been installed for verification to the building owner. |
Completed Value: Undisclosed |
6. |
Audiometric Test Room and Control Room within the Ambulatory Care Centre, Hospital Tengku AmpuanAfzan, Kuantan, Pahang D.M. project. |
Mason Acoustics (M) Sdn. Bhd. |
Commissioning measurements of the Audiometric Booths from the HVAC Systems and intrusive external noise sources. Test was conducted in accordance with the Factories and Machinery Act, Factories and Machinery (Noise Exposure) Regulation, 1989. |
Completed Value: Undisclosed |
7. |
Multipurpose Hall cum Auditorium within Loh Guan Lye Specialist Centre, Penang. |
Imaging Space Design Sdn. Bhd. |
Sound insulation and room acoustic design for the said project. |
Completed Value: Undisclosed |
8. |
Auditorium within The Island Hospital, Penang |
Imaging Space Design Sdn. Bhd. |
Sound Insulation against rain noise impact for the Auditorium facility. Particular design attention was placed to achieve low noise levels within the auditorium from adjacent chiller and cooling tower equipment. |
|
9. |
Auditorium within The Gleneagles Medical Centre, Penang |
Imaging Space Design Sdn. Bhd. |
Room acoustic and sound insulation and mechanical noise control design for the Auditorium and supporting facilities. Particular design attention was placed to achieve low noise levels within the auditorium from adjacent chiller and cooling tower equipment. |
On-Going Value: |
10. |
The design, build, equipping, T&C of InstitutKanser Negara (IKN), Putrajaya |
KiaraTeratai Sdn. Bhd. |
Sound Insulation, Room Acoustics, Mechanical ACMV Noise Control and Vibration Control design for the various facilities located within the building. |
On going Value: RM700M |